Lithium battery specifications for 100Ah Li-Ion (12V/24V) | Clayton Power

Lithium Ion Batteries | Specifications

Lithium Battery type:

 

12V – 100Ah Lithium Ion Battery

 

24V – 100Ah Lithium Ion Battery

 

Model no.

 

012-00002GF

 

012-00004GF

 

Nominal capacity

 

100Ah

 

100Ah

 

Nominal battery voltage

 

12 VDC

 

24 VDC

 

Operation voltage discharge

 

9.2 VDC

 

18.4 VDC

 

Operation voltage charge

 

15 VDC

 

30 VDC

 

Cell voltage min cut-off

 

2.3 VDC

 

2.3 VDC

 

Cell voltage max cut-off

 

4.2 VDC

 

4.2 VDC

 

Continuous discharge current

 

100 A

 

100 A

 

Max discharge Impulse current:


10 min.


5 sec.


uSec.

 

 


200 A (temperature controlled)


>500 A


>1000 A

 

 


200 A (temperature controlled)


>500 A


>1000 A

 

Continuous charge current

 

100 A

 

100 A

 

Standard charge/discharge current

 

50 A

 

50 A

 

Lifecycle 80%DOD

 

>2000

 

>2000

 

Lifecycle 70%DOD

 

>5000

 

>5000

 

Operating temperature

 

-40°C~+50°C

 

-40°C~+50°C

 

Cooling

 

Forced fan

 

Forced fan

 

Inputs (wakeup function)

 

3

 

3

 

Outputs (Open Collector)

 

2

 

2

 

Communication

 

CAN (SAE J1939) - CP SW

 

CAN (SAE J1939) - CP SW

 

Parallel connection

 

1 to 20

 

1 to 20

 

Self-discharge rate per month (Sleep mode)

 

<3%

 

<3%

 

Operating mode consumption

 

350mA

 

180mA

 

Sleep mode consumption

 

<2mA

 

<2mA

 

Connection terminals

 

M8 screw

 

M8 screw

 

Chemistry

 

LiFeYPO4

 

LiFeYPO4

 

Protection

 

IP21

 

IP21

 

Watt hours

 

1320Wh

 

2640Wh

 

Weight of cells

 

14kg

 

28kg

 

Weight

 

19kg

 

37,2kg

 

Dimensions (WxHxD)

 

192x274x301 mm

 

192x274x558 mm

 

Package weight (total)

 

21kg

 

39kg

 

Package dimensions WxHxD (mm)

 

285x330x390

 

330x360x685

 

Approvals and standards:

 
 

2006/95/EC (Safety directive)

 

The following harmonized standards have been applied: EN 60950-1:2001+ A11:2004 (LVD)

 

2004/108/EC (EMC directive)

 

The following harmonized standards have been applied: EN 61000-6-3: 2007 Emission hold equipment ?EN 61000-6-2: 2007 Immunity industrial

 

CE